Details

EC 22 Ø22 mm, brushless, 240 Watt, with Hall sensors | Heavy Duty – for applications in oil

Part number 426450

EC 22 Ø22 mm, brushless, 240 Watt, with Hall sensors

For more information, please contact our sales support with the request form. Thank you

Specifications

Technical illustrations

Information: Drawings are not to scale.

Values at nominal voltage
Nominal voltage 48 V
No load speed 13100 rpm
No load current 177 mA
Nominal speed 11500 rpm
Nominal torque (max. continuous torque) 52.6 mNm
Nominal current (max. continuous current) 1.67 A
Stall torque 460 mNm
Stall current 13.4 A
Max. efficiency 79 %
Characteristics
Terminal resistance 3.59 Ω
Terminal inductance 0.626 mH
Torque constant 34.4 mNm/A
Speed constant 278 rpm/V
Speed / torque gradient 29 rpm/mNm
Mechanical time constant 2.31 ms
Rotor inertia 7.63 gcm²
Thermal data
Thermal resistance housing-ambient 9.12 K/W
Thermal resistance winding-housing 0.92 K/W
Thermal time constant winding 5.84 s
Thermal time constant motor 462 s
Ambient temperature -55...+200 °C
Max. winding temperature +240 °C
Mechanical data
Bearing type Waelzlager
Max. speed 20000 rpm
Axial play 0 mm, at radial load < 5 N
0.14 mm, at radial load > 5 N
Radial play 0.025 mm
Max. axial load (dynamic) 8 N
Max. force for press fits (static) 98 N
(static, shaft supported) 250 N
Max. radial load 16 N, 5 mm from flange
Other specifications
Number of pole pairs 1
Number of phases 3
Number of autoclave cycles 0
Product
Weight 237 g
  • Operating Range

    Continuous operation range
   
     
    Short term operation range
   

Description

The electronically commutated EC motors are characterized especially by their favorable torque characteristics, high power, extremely broad speed range and, of course, by their unsurpassed service life.

Videos